OSHA SearchOSHA records by employer

Marcelino Stucco, Inc.: OSHA inspections and violations

Orlando, Florida · Masonry Contractors · NAICS 238140

3inspections
7citation items
$6,952current penalties
Mar 19, 2015last inspection

Marcelino Stucco, Inc. has 3 OSHA inspections on record in Florida, the first in 2006.

OSHA's last visit started on Mar 19, 2015 as a planned inspection, in Jacksonville.

Across those inspections OSHA issued 7 citation items: 7 serious.

OSHA proposed $11,450 in penalties. After settlements and reviews the total is $6,952, down 39%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Marcelino Stucco, Inc. averages $4,860 over 1 cited inspection in that time.

Marcelino Stucco, Inc.: OSHA citation items per year, 2006 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Marcelino Stucco, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340481191 OPENED MAR 19, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 12, 2018

6913 103rd Street Raceway, Jacksonville, FL 32210 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,600$960Apr 14, 2015Final
Citation 1, item 2
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$4,900$2,940Apr 14, 2015Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,600$960Apr 14, 2015Final

Inspection 339994881 OPENED OCT 8, 2014Closed

Planned · Partial · Safety · 2 employees at the site · Closed Feb 13, 2017

7407 W. Colonial Drive, Orlando, FL 32818 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,800$1,680Oct 14, 2014Final

Inspection 310296041 OPENED OCT 3, 2006Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 13, 2006

8865 Commodity Circle, Orlando, FL 32819 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$225$169Nov 20, 2006Closed
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$225$169Nov 20, 2006Closed
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$100$75Nov 20, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.