Marco Sanchez: OSHA inspections and violations

Edmond, Oklahoma · Framing Contractors · NAICS 238130

1inspections
4citation items
$4,810current penalties
Jul 21, 2016last inspection

Marco Sanchez has one OSHA inspection on record in Oklahoma.

OSHA opened it on Jul 21, 2016 as a planned inspection, in Edmond.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $4,810 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Marco Sanchez averages $4,810 over 1 cited inspection in that time.

Marco Sanchez: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Marco Sanchez again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341786010 OPENED JUL 21, 2016Closed

Planned · Partial · Safety · 2 employees at the site · Closed Dec 8, 2016

501 Nw 180th, Edmond, OK 73012 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,138$2,138Sep 28, 2016Final
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Sep 28, 2016Final
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Sep 28, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,672$2,672Sep 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.