OSHA SearchOSHA records by employer

Marcos Antonio Delcid Turcios: OSHA inspections and violations

Houston, Texas · Framing Contractors · NAICS 238130

1inspections
3citation items
$2,074current penalties
Feb 15, 2022last inspection

OSHA inspectors have visited Marcos Antonio Delcid Turcios in Texas one time.

It opened on Feb 15, 2022 as a planned inspection, in Houston.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $3,457; today they stand at $2,074, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Marcos Antonio Delcid Turcios averages $2,074 across 1 cited inspection.

Marcos Antonio Delcid Turcios: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

53 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Marcos Antonio Delcid Turcios and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345783203 OPENED FEB 15, 2022Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 25, 2024

1733 Ennis, Houston, TX 77003 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$3,108$1,865Mar 16, 2022Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Mar 16, 2022Final
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$349$209Mar 16, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.