OSHA SearchOSHA records by employer

Mario Elizondo: OSHA inspections and violations

San Antonio, Texas · Masonry Contractors · NAICS 238140

1inspections
9citation items
$3,200current penalties
May 5, 2015last inspection

OSHA inspectors have visited Mario Elizondo in Texas one time.

It opened on May 5, 2015 as a planned inspection, in San Antonio.

In all, OSHA issued 9 citation items: 9 serious.

The proposed penalties came to $12,800; today they stand at $3,200, 75% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mario Elizondo averages $3,200 across 1 cited inspection.

Mario Elizondo: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Mario Elizondo and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340612563 OPENED MAY 5, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 15, 2016

13135 Lovela Bend, San Antonio, TX 78254 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,600$400May 29, 2015Final
Citation 1, item 1b
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0May 29, 2015Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,600$400May 29, 2015Final
Citation 1, item 3
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,600$400May 29, 2015Final
Citation 1, item 4
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,600$400May 29, 2015Final
Citation 1, item 5
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,600$400May 29, 2015Final
Citation 1, item 6
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,600$400May 29, 2015Final
Citation 1, item 7
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,600$400May 29, 2015Final
Citation 1, item 8
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,600$400May 29, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.