OSHA SearchOSHA records by employer

Mario Gomez Palacios: OSHA inspections and violations

Candler, North Carolina · Siding Contractors · NAICS 238170

1inspections
4citation items
$11,600current penalties
Feb 22, 2023last inspection

OSHA has inspected Mario Gomez Palacios once in North Carolina.

The inspection began on Feb 22, 2023 as a planned inspection, in Candler.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $11,600 and still stand at $11,600.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Mario Gomez Palacios averages $11,600 (1 cited inspection).

Mario Gomez Palacios: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Mario Gomez Palacios and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346533656 OPENED FEB 22, 2023Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 31, 2025

154 Marathon Lane, Candler, NC 28715 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$2,900$2,900Mar 22, 2023Final
Citation 1, item 2
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$2,900$2,900Mar 22, 2023Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,900$2,900Mar 22, 2023Final
Citation 1, item 4
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,900$2,900Mar 22, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(b)(7)

(7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

Other siding contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.