OSHA SearchOSHA records by employer

Mario Gonzalez JR.: OSHA inspections and violations

Conroe, Texas · Framing Contractors · NAICS 238130

1inspections
8citation items
$9,832current penalties
Feb 25, 2020last inspection

OSHA inspectors have visited Mario Gonzalez JR. in Texas one time.

It opened on Feb 25, 2020 as a planned inspection, in Conroe.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The penalties, $9,832 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mario Gonzalez JR. averages $9,832 across 1 cited inspection.

Mario Gonzalez JR.: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

56 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Mario Gonzalez JR. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344661251 OPENED FEB 25, 2020Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jun 28, 2024

1362 Wilson Road, Conroe, TX 77304 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,892$2,892May 28, 2020Final
Citation 1, item 2a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,892$2,892May 28, 2020Final
Citation 1, item 2b
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$0$0May 28, 2020Final
Citation 1, item 2c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0May 28, 2020Final
Citation 1, item 2d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 28, 2020Final
Citation 1, item 2e
29 CFR 1926.451(f)(16) · Scaffolds, general requirements
Serious$0$0May 28, 2020Final
Citation 1, item 3
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$4,048$4,048May 28, 2020Final
Citation 2, item 1
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0May 28, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.