OSHA SearchOSHA records by employer

Mark Construction Services, Inc.: OSHA inspections and violations

Scranton, Pennsylvania · Commercial and Institutional Building Construction · NAICS 236220

4inspections
8citation items
$4,520current penalties
Nov 13, 2018last inspection

Since 2005, OSHA inspectors have visited Mark Construction Services, Inc. in Pennsylvania 4 times.

The most recent inspection opened on Nov 13, 2018 on a referral, in Plains Township.

In all, OSHA issued 8 citation items: 6 serious and 2 other-than-serious.

The proposed penalties came to $7,638; today they stand at $4,520, 41% less.

The rule cited most here is 1926.760 (fall protection), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mark Construction Services, Inc. averages $3,400 across 1 cited inspection.

Mark Construction Services, Inc.: OSHA citation items per year, 2005 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

295employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Mark Construction Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343598843 OPENED NOV 13, 2018Closed

Referral · Partial · Safety · 4 employees at the site · Closed Feb 14, 2019

Parking Lot 5 North River Street, Plains Township, PA 18705 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,696$3,400Nov 30, 2018Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$2,217$0Nov 30, 2018Final
Citation 1, item 2b
29 CFR 1926.1053(b)(13) · Ladders in construction
Other-than-serious$0$0Nov 30, 2018Final

Inspection 312295348 OPENED MAR 2, 2010Closed

Complaint · Complete · Safety · 1 employee at the site · Closed Mar 5, 2010

Main & Market Streets, Nanticoke, PA 18634 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307916643 OPENED AUG 25, 2005Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Oct 3, 2005

Lackawanna College, Scranton, PA 18503 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$375$245Sep 23, 2005Closed
Citation 1, item 2
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$375$245Sep 23, 2005Closed

Inspection 307915025 OPENED MAY 23, 2005Closed

Referral · Complete · Safety · 1 employee at the site · Closed Jun 9, 2005

Lackawanna College, Scranton, PA 18503 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$375$245May 31, 2005Closed
Citation 1, item 2
29 CFR 1926.760(e)(2) · Fall protection
Serious$375$240May 31, 2005Closed
Citation 1, item 3
29 CFR 1926.760(d)(3) · Fall protection
Serious$225$145May 31, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.760 · Fall protection

Other commercial and institutional building construction employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.