OSHA SearchOSHA records by employer

Martel Marine Panels LLC: OSHA inspections and violations

Thomasville, Georgia · Other Millwork (including Flooring) · NAICS 321918

1inspections
2citation items
$4,547current penalties
Oct 8, 2019last inspection

Martel Marine Panels LLC has one OSHA inspection on record in Georgia.

OSHA opened it on Oct 8, 2019 as a planned inspection, in Thomasville.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,578 in penalties. After settlements and reviews the total is $4,547, down 40%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Martel Marine Panels LLC averages $4,547 over 1 cited inspection in that time.

Martel Marine Panels LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Martel Marine Panels LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344363064 OPENED OCT 8, 2019Closed

Planned · Partial · Safety · 15 employees at the site · Closed Nov 22, 2019

105 Genesis Parkway, Thomasville, GA 31792 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,789$2,273Nov 5, 2019Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,789$2,273Nov 5, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

Other other millwork (including flooring) employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.