OSHA SearchOSHA records by employer

Martin Midstream Partners L.P.: OSHA inspections and violations

Plainview, Texas · Phosphatic Fertilizer Manufacturing · NAICS 325312

2inspections
6citation items
$27,900current penalties
Jul 24, 2018last inspection

Since 2018, OSHA inspectors have visited Martin Midstream Partners L.P. in Texas 2 times.

The most recent inspection opened on Jul 24, 2018 as a planned inspection, in Plainview.

In all, OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

The proposed penalties came to $36,954; today they stand at $27,900, 24% less.

The rule cited most here is 1910.119 (process safety management), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Martin Midstream Partners L.P. averages $13,950 across 2 cited inspections.

Martin Midstream Partners L.P.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Martin Midstream Partners L.P. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343334421 OPENED JUL 24, 2018Closed

Planned · Partial · Health · 55 employees at the site · Closed May 11, 2019

1920 State Highway 194, Plainview, TX 79072 · Phosphatic Fertilizer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.119(f)(3) · Process safety management
Other-than-serious$5,543$5,543Jan 9, 2019Final
Citation 1, item 2
29 CFR 1910.119(g)(3) · Process safety management
Other-than-serious$7,391$7,391Jan 9, 2019Final
Citation 1, item 3a
29 CFR 1910.119(j)(2) · Process safety management
Serious$12,934$7,760Jan 9, 2019Final
Citation 1, item 3b
29 CFR 1910.119(j)(4)(i) · Process safety management
Serious$0$0Jan 9, 2019Final
Citation 1, item 4
29 CFR 1910.119(o)(4) · Process safety management
Serious$5,543$3,880Jan 9, 2019Final

Inspection 343361960 OPENED JUL 24, 2018Closed

Complaint · Partial · Health · 55 employees at the site · Closed Feb 6, 2019

1920 Hwy 194 West, Plainview, TX 79072 · Phosphatic Fertilizer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$5,543$3,326Jan 17, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.119 · Process safety management

29 CFR 1910.119(f)(3)

(3) The operating procedures shall be reviewed as often as necessary to assure that they reflect current operating practice, including changes that result from changes in process chemicals, technology, and equipment, and changes to facilities. The employer shall certify annually that these operating procedures are current and accurate.

29 CFR 1910.119(g)(3)

(3) Training documentation. The employer shall ascertain that each employee involved in operating a process has received and understood the training required by this paragraph. The employer shall prepare a record which contains the identity of the employee, the date of training, and the means used to verify that the employee understood the training.

29 CFR 1910.119(j)(2)

(2) Written procedures. The employer shall establish and implement written procedures to maintain the on-going integrity of process equipment.

29 CFR 1910.22 · Walking-working surfaces

Other phosphatic fertilizer manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.