OSHA SearchOSHA records by employer

Masonry Engineers, Inc: OSHA inspections and violations

Bountiful, Utah · Masonry Contractors · NAICS 238140

4inspections
12citation items
$5,020current penalties
Aug 24, 2017last inspection

Masonry Engineers, Inc has 4 OSHA inspections on record in Utah, the first in 1995.

OSHA's last visit started on Aug 24, 2017 as a planned inspection, in Layton.

Across those inspections OSHA issued 12 citation items: 12 serious.

OSHA proposed $7,420 in penalties. After settlements and reviews the total is $5,020, down 32%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (9 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Masonry Engineers, Inc averages $1,500 over 1 cited inspection in that time.

Masonry Engineers, Inc: OSHA citation items per year, 1995 to 2017
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Masonry Engineers, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342578770 OPENED AUG 24, 2017Closed

Planned · Partial · Safety · 7 employees at the site · Closed Nov 24, 2017

Gentile St & Fort Ln Cvs Pharmacy, Layton, UT 84041 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$750Sep 14, 2017Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 14, 2017Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$750Sep 14, 2017Final

Inspection 306617762 OPENED JAN 25, 2005Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 31, 2005

590 N.state, Lindon, UT 84042 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$600Mar 15, 2005Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Mar 15, 2005Closed
Citation 1, item 1c
29 CFR 1926.451(f)(1) · Scaffolds, general requirements
Serious$0$0Mar 15, 2005Closed
Citation 1, item 1d
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Mar 15, 2005Closed
Citation 1, item 1e
29 CFR 1926.454(c) · Scaffold training
Serious$0$0Mar 15, 2005Closed

Inspection 126801091 OPENED APR 7, 1999Closed

Planned · Complete · Safety · 7 employees at the site · Closed May 25, 1999

1270 S 1380 W, Orem, UT 84057 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$960$960Apr 19, 1999Closed
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$960$960Apr 19, 1999Closed

Inspection 126745082 OPENED MAY 11, 1995Closed

Planned · Partial · Safety · 5 employees at the site · Closed Aug 31, 1995

500 South & I-15, Bountiful, UT 84010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,000$1,000May 22, 1995Closed
Citation 1, item 1b
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$0$0May 22, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(4)

(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.454 · Scaffold training

29 CFR 4030.1320