OSHA SearchOSHA records by employer

Masonry Preservation Services Inc: OSHA inspections and violations

Wilkes Barre, Pennsylvania · Masonry Contractors · NAICS 238140

8inspections
9citation items
$11,875current penalties
Jul 8, 2015last inspection

Since 1999, OSHA inspectors have visited Masonry Preservation Services Inc in Pennsylvania 8 times.

The most recent inspection opened on Jul 8, 2015 after a fatality or catastrophe, in Danville.

In all, OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

The proposed penalties came to $16,000; today they stand at $11,875, 26% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Masonry Preservation Services Inc averages $10,500 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Masonry Preservation Services Inc: OSHA citation items per year, 1999 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Masonry Preservation Services Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340762251 OPENED JUL 8, 2015Closed

Fatality or catastrophe · Complete · Safety · 8 employees at the site · Closed Jan 15, 2016

100 N Academy Ave, Danville, PA 17821 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 8, 2015 (fatal): Employee falls from scaffold and is killed.

At 12:00 p.m. on July 8, 2015, an employee was preparing to move the mast-climber scaffold down to the ground. Witnesses reported they thought he stepped on a 1/2 inch piece of plywood that was covering the mast hole. They believe the plywood broke and he fell to the deck below. The witnesses did not see him fall through the plywood. The employee fell 90 feet, and was killed due to multiple traumatic impact injuries. The employee was not wearing any fall protection.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$7,000$7,000Dec 17, 2015Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$7,000$3,500Dec 17, 2015Final

Inspection 339908477 OPENED AUG 19, 2014Closed

Planned · Partial · Safety · 20 employees at the site · Closed Aug 22, 2014

500 Vine Street, Scranton, PA 18509 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312287949 OPENED NOV 4, 2008Closed

Planned · Complete · Safety · 5 employees at the site · Closed Dec 22, 2008

71 S. Franklin St., Wilkes Barre, PA 18701 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,125$780Dec 9, 2008Closed

Inspection 310233093 OPENED MAY 5, 2008Closed

Referral · Partial · Health · 40 employees at the site · Closed Jun 18, 2008

Kirby Bldg, S Washington St, Wilkes Barre, PA 18701 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(6)(i) · Respiratory protection
Other-than-serious$0$0May 16, 2008Closed
Citation 1, item 2
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0May 16, 2008Closed

Inspection 310233101 OPENED MAY 5, 2008Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jun 12, 2008

Kirby Building, S. Washington Street, Wilkes Barre, PA 18701 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$500$350May 29, 2008Closed

Inspection 307915157 OPENED MAY 25, 2005Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Aug 3, 2005

Luzerne County Courthouse, Wilkes Barre, PA 18703 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308167568 OPENED SEP 20, 2004Closed

Referral · Partial · Health · 4 employees at the site · Closed Sep 21, 2004

2400 Chew Street, Allentown, PA 18104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301043683 OPENED MAY 10, 1999Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Jun 9, 1999

North River Street, Wilkes Barre, PA 18702 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(ii) · Scaffolds, general requirements
Serious$375$245May 19, 1999Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0May 19, 1999Closed
Citation 2, item 2
29 CFR 1926.1053(a)(24) · Ladders in construction
Other-than-serious$0$0May 19, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(6)(i)

(i) Obtain a written recommendation regarding the employee's ability to use the respirator from the PLHCP. The recommendation shall provide only the following information:

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(a)(24)

(24) The side rails of through or side-step fixed ladders shall extend 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder. For a parapet ladder, the access level shall be the roof if the parapet is cut to permit passage through the parapet; if the parapet is continuous, the access level shall be the top of the parapet.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.