OSHA SearchOSHA records by employer

Master Roofing - Siding, LLP: OSHA inspections and violations

Manteo, North Carolina · Roofing Contractors · NAICS 238160

2inspections
4citation items
$10,987current penalties
Feb 21, 2023last inspection

Since 2022, OSHA inspectors have visited Master Roofing - Siding, LLP in North Carolina 2 times.

The most recent inspection opened on Feb 21, 2023 after a fatality or catastrophe, in Frisco.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $10,987 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Master Roofing - Siding, LLP averages $5,494 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Master Roofing - Siding, LLP: OSHA citation items per year, 2022 to 2023
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

236employers cited

18 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Master Roofing - Siding, LLP and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346474687 OPENED FEB 21, 2023Closed

Fatality or catastrophe · Partial · Safety · 3 employees at the site · Closed Aug 1, 2023

50224 S. Buccaneer Drive, Frisco, NC 27936 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 23, 2023 (fatal): Two employees are electrocuted while completing roofing acti

At 12:00 noon on January 23, 2023, subcontractor employees were completing roofing activities on a two-story residential home. Employee #1, the company owner, was lowering a 32-foot shingle hoist from the front right corner of the residential home when he lost control of the hoist and it contacted the 7,200-volt electrical distribution lines located approximately 23-1/2 feet away from the home. Once the shingle hoist contacted the electrical distribution line employee #1 was electrocuted. Employee #2 saw employee #1 and attempted to push him off of the power line when he also was electrocuted. Both employees were transported to the hospital where employee #2 died from his injuries on February 6, 2023.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,687$4,687Jul 20, 2023Final

Inspection 345759823 OPENED FEB 2, 2022Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Mar 10, 2022

962 Marshall C Collins Drive, Manteo, NC 27954 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,100$2,100Feb 24, 2022Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,100$2,100Feb 24, 2022Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,100$2,100Feb 24, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.