OSHA SearchOSHA records by employer

Masters Builders Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Roofing Contractors · NAICS 238160

1inspections
7citation items
$14,668current penalties
Oct 12, 2016last inspection

Masters Builders Inc. has one OSHA inspection on record in Pennsylvania.

OSHA opened it on Oct 12, 2016 on a referral, in Philadelphia.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $14,668 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.1053, ladders in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Masters Builders Inc. averages $14,668 over 1 cited inspection in that time.

Masters Builders Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Masters Builders Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341833598 OPENED OCT 12, 2016Closed

Referral · Partial · Safety · 10 employees at the site · Closed Sep 30, 2022

629 E Girard Ave, Philadelphia, PA 19125 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$3,259$3,259Apr 12, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,803$3,803Apr 12, 2017Final
Citation 1, item 3a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,803$3,803Apr 12, 2017Final
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Apr 12, 2017Final
Citation 1, item 4
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$3,803$3,803Apr 12, 2017Final
Citation 1, item 5a
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Apr 12, 2017Final
Citation 1, item 5b
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$0$0Apr 12, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(6)

(6) Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.