OSHA SearchOSHA records by employer

Max Nitz Polishing: OSHA inspections and violations

Baroda, Michigan · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

2inspections
9citation items
$2,400current penalties
Mar 9, 2018last inspection

OSHA has inspected Max Nitz Polishing 2 times in Michigan since 2017.

The latest one began on Mar 9, 2018 as part of a related case, in Baroda.

Those inspections ended with 9 citation items: 8 serious and 1 other-than-serious.

Penalties were first proposed at $2,400 and still stand at $2,400.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Max Nitz Polishing averages $1,200 (2 cited inspections).

Max Nitz Polishing: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

650employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Max Nitz Polishing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343002911 OPENED MAR 9, 2018Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Feb 26, 2019

169 Hinchman Rd, Baroda, MI 49101 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$500$500May 9, 2018Final
Citation 1, item 2
29 CFR 1910.305(j)(2)(i) · Electrical wiring methods
Serious$700$700May 9, 2018Final
Citation 1, item 3
29 CFR 408.14923(4)
Serious$400$400May 9, 2018Final
Citation 2, item 1
29 CFR 408.10835(3)
Other-than-serious$0$0May 9, 2018Final

Inspection 342743937 OPENED NOV 13, 2017Closed

Complaint · Partial · Health · 8 employees at the site · Closed Jul 8, 2019

169 Hinchman Rd, Baroda, MI 49101 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$400$400Mar 9, 2018Final
Citation 1, item 1b
29 CFR 408.1014J
Serious$0$0Mar 9, 2018Final
Citation 1, item 1c
29 CFR 408.1014C
Serious$0$0Mar 9, 2018Final
Citation 1, item 2a
29 CFR 408.10835(3)
Serious$400$400Mar 9, 2018Final
Citation 1, item 2b
29 CFR 325.47201(2)
Serious$0$0Mar 9, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(j)(2)(i)

(2) Receptacles, cord connectors, and attachment plugs (caps). (i) All 15- and 20-ampere attachment plugs and connectors shall be constructed so that there are no exposed current-carrying parts except the prongs, blades, or pins. The cover for wire terminations shall be a part that is essential for the operation of an attachment plug or connector (dead-front construction). Attachment plugs shall be installed so that their prongs, blades, or pins are not energized unless inserted into an energized receptacle. No receptacles may be installed so as to require an energized attachment plug as its source of supply.

Other electroplating, plating, polishing, anodizing, and coloring employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.