Inspection 348432204 OPENED AUG 12, 2025Closed
14000 Leetsbir Road, Sturtevant, WI 53177 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Sturtevant, Wisconsin · All Other Automotive Repair and Maintenance · NAICS 811198
Mayer Repair LLC has 2 OSHA inspections on record in Wisconsin, the first in 2024.
OSHA's last visit started on Aug 12, 2025 to follow up on an earlier case, in Sturtevant.
Across those inspections OSHA issued 6 citation items: 6 serious.
OSHA proposed $24,116 in penalties. After settlements and reviews the total is $21,750, down 10%.
Most often, OSHA cited 1910.147, lockout/tagout (3 items).
For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Mayer Repair LLC averages $21,750 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Wisconsin · latest 90 days of OSHA records
229employers cited
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Wisconsin
Checking a subcontractor, a client or your own company? Watch Mayer Repair LLC and get notified the morning OSHA posts a new citation for it.
Watch this company14000 Leetsbir Road, Sturtevant, WI 53177 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
14000 Leetsbir Road, Sturtevant, WI 53177 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps
Incident on Nov 11, 2024 (fatal): Employee sustains burns while plasma cutting drum top, later
At 11:00 a.m. on November 11, 2024, an employee working as a mechanic/welder for an automotive shop was using a a plasma cutter to cut the top off a 55-gallon metal drum. The employee was unaware the drum contained flammable liquids. The instant the plasma cutter touched the drum, the drum exploded upwards and came to rest in the adjacent stall. The explosion caused a localized fire due to the flammable liquid in the drum. The employee was sustained multiple contusions and burns to his abdomen, face, chest and arms in the explosion. The employee was flown to the emergency department of a medical center. At 6:52 p.m. on November 19, 2024, the employee died from his injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $4,729 | $3,300 | Mar 21, 2025 | Final |
| Citation 1, item 1b 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 21, 2025 | Final |
| Citation 1, item 1c 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 21, 2025 | Final |
| Citation 1, item 2 29 CFR 1910.252(a)(3)(i) · Welding fire safety |
Serious | $16,550 | $16,550 | Mar 21, 2025 | Final |
| Citation 1, item 3a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $2,837 | $1,900 | Mar 21, 2025 | Final |
| Citation 1, item 3b 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Serious | $0 | $0 | Mar 21, 2025 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(f)(6)(ii)
(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.
29 CFR 1910.147(c)(1)
(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.