OSHA SearchOSHA records by employer

Mayer Repair LLC: OSHA inspections and violations

Sturtevant, Wisconsin · All Other Automotive Repair and Maintenance · NAICS 811198

2inspections
6citation items
$21,750current penalties
Aug 12, 2025last inspection

Mayer Repair LLC has 2 OSHA inspections on record in Wisconsin, the first in 2024.

OSHA's last visit started on Aug 12, 2025 to follow up on an earlier case, in Sturtevant.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $24,116 in penalties. After settlements and reviews the total is $21,750, down 10%.

Most often, OSHA cited 1910.147, lockout/tagout (3 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Mayer Repair LLC averages $21,750 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Mayer Repair LLC: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Mayer Repair LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348432204 OPENED AUG 12, 2025Closed

Follow-up · Partial · Safety · 9 employees at the site · Closed Aug 15, 2025

14000 Leetsbir Road, Sturtevant, WI 53177 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347894362 OPENED NOV 21, 2024Open

Fatality or catastrophe · Complete · Safety · 12 employees at the site · Open

14000 Leetsbir Road, Sturtevant, WI 53177 · All Other Automotive Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on Nov 11, 2024 (fatal): Employee sustains burns while plasma cutting drum top, later

At 11:00 a.m. on November 11, 2024, an employee working as a mechanic/welder for an automotive shop was using a a plasma cutter to cut the top off a 55-gallon metal drum. The employee was unaware the drum contained flammable liquids. The instant the plasma cutter touched the drum, the drum exploded upwards and came to rest in the adjacent stall. The explosion caused a localized fire due to the flammable liquid in the drum. The employee was sustained multiple contusions and burns to his abdomen, face, chest and arms in the explosion. The employee was flown to the emergency department of a medical center. At 6:52 p.m. on November 19, 2024, the employee died from his injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$4,729$3,300Mar 21, 2025Final
Citation 1, item 1b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Mar 21, 2025Final
Citation 1, item 1c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Mar 21, 2025Final
Citation 1, item 2
29 CFR 1910.252(a)(3)(i) · Welding fire safety
Serious$16,550$16,550Mar 21, 2025Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,837$1,900Mar 21, 2025Final
Citation 1, item 3b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Mar 21, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.252 · Welding fire safety

Other all other automotive repair and maintenance employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.