Inspection 345184832 OPENED MAR 8, 2021Closed
418 Portage Street, Gallitzin, PA 16641 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Gallitzin, Pennsylvania · Site Preparation Contractors · NAICS 238910
Mazz's Elite Contracting has 2 OSHA inspections on record in Pennsylvania, the first in 2020.
OSHA's last visit started on Mar 8, 2021 to follow up on an earlier case, in Gallitzin.
Across those inspections OSHA issued 2 citation items: 2 other-than-serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1926.651, excavations (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mazz's Elite Contracting averages $0 over 1 cited inspection in that time.
Pennsylvania · latest 90 days of OSHA records
285employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Mazz's Elite Contracting and get notified the morning OSHA posts a new citation for it.
Watch this company418 Portage Street, Gallitzin, PA 16641 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
418 Portage Street, Gallitzin, PA 16641 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.651(j)(2) · Excavations |
Other-than-serious | $0 | $0 | Dec 15, 2020 | Final |
| Citation 1, item 1b 29 CFR 1926.651(k)(1) · Excavations |
Other-than-serious | $0 | $0 | Dec 15, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.651(j)(2)
(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.
29 CFR 1926.651(k)(1)
(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.