OSHA SearchOSHA records by employer

McAgcc-Magtftc, MCCS: OSHA inspections and violations

29 Palms, California · National Security · NAICS 928110

1inspections
8citation items
$0current penalties
Mar 13, 2015last inspection

McAgcc-Magtftc, MCCS has one OSHA inspection on record in California.

OSHA opened it on Mar 13, 2015 as a planned inspection, in 29 Palms.

From that inspection OSHA issued 8 citation items: 8 serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all public administration employers the median penalty per cited inspection since 2015 is $0. McAgcc-Magtftc, MCCS averages $0 over 1 cited inspection in that time.

McAgcc-Magtftc, MCCS: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,120employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch McAgcc-Magtftc, MCCS and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340521871 OPENED MAR 13, 2015Closed

Planned · Complete · Safety · Federal government · 120 employees at the site · Closed Apr 4, 2016

Mccs Golf Course Box 788150, 29 Palms, CA 92278 · National Security · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Sep 9, 2015Final
Citation 1, item 2
29 CFR 1910.303(h)(5)(iii)(b) · Electrical equipment, general requirements
Serious$0$0Sep 9, 2015Final
Citation 1, item 3
29 CFR 1910.176(b) · Material storage and aisles
Serious$0$0Sep 9, 2015Final
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Sep 9, 2015Final
Citation 1, item 5
29 CFR 1910.304(b)(3)(i) · Grounding and circuit protection
Serious$0$0Sep 9, 2015Final
Citation 1, item 6
29 CFR 1910.36(g)(2) · Exit route design
Serious$0$0Sep 9, 2015Final
Citation 1, item 7
29 CFR 1910.303(b)(1)(viii) · Electrical equipment, general requirements
Serious$0$0Sep 9, 2015Final
Citation 1, item 8 Serious$0$0Sep 9, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.176(b)

(b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)(viii)

(viii) Other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.36 · Exit route design

29 CFR 1960.30

Other national security employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.