OSHA SearchOSHA records by employer

McCashion Brothers Holding Co. LLC: OSHA inspections and violations

Albany, New York · Masonry Contractors · NAICS 238140

5inspections
16citation items
$21,641current penalties
Aug 19, 2025last inspection

McCashion Brothers Holding Co. LLC has 5 OSHA inspections on record in New York, the first in 2006.

OSHA's last visit started on Aug 19, 2025 after a complaint, in Latham, and the case has not closed yet.

Across those inspections OSHA issued 16 citation items: 10 serious and 6 other-than-serious.

OSHA proposed $23,516 in penalties. After settlements and reviews the total is $21,641, down 8%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (9 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. McCashion Brothers Holding Co. LLC averages $4,885 over 4 cited inspections in that time.

McCashion Brothers Holding Co. LLC: OSHA citation items per year, 2006 to 2025
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

365employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch McCashion Brothers Holding Co. LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348452178 OPENED AUG 19, 2025Open

Complaint · Partial · Safety · 12 employees at the site · Open

784 Troy Schenectady Rd., Latham, NY 12110 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,837$2,837Feb 11, 2026Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$4,965$4,965Feb 11, 2026Final
Citation 1, item 3
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$2,837$2,837Feb 11, 2026Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,547$3,547Feb 11, 2026Final

Inspection 346667694 OPENED MAY 1, 2023Open

Referral · Partial · Safety · 10 employees at the site · Open

579 Troy-schenectady Rd, Latham, NY 12110 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.150(a)(1) · Fire protection
Serious$4,688$2,813Sep 25, 2023Final

Inspection 344592779 OPENED JAN 28, 2020Closed

Referral · Partial · Safety · 6 employees at the site · Closed Feb 24, 2023

1988 Central Ave, Albany, NY 12205 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$325$325Feb 25, 2020Final

Inspection 343457669 OPENED SEP 12, 2018Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Apr 3, 2023

1651 Western Ave., Albany, NY 12203 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,217$2,217Sep 19, 2018Final

Inspection 309209617 OPENED OCT 11, 2006Closed

Planned · Complete · Safety · 6 employees at the site · Closed May 22, 2012

Shaker Pine Plaza, Colonie, NY 12205 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$450$450Dec 20, 2006Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$600$600Dec 20, 2006Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$600$600Dec 20, 2006Closed
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$450$450Dec 20, 2006Closed
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0Dec 20, 2006Closed
Citation 2, item 2
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Other-than-serious$0$0Dec 20, 2006Closed
Citation 2, item 3
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Dec 20, 2006Closed
Citation 2, item 4
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Other-than-serious$0$0Dec 20, 2006Closed
Citation 2, item 5
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Other-than-serious$0$0Dec 20, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.