Since 2009, OSHA inspectors have visited McCoy Construction, Inc. in Florida 4 times.

The most recent inspection opened on Aug 29, 2024 on a referral, in Marco Island.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $11,538; today they stand at $7,163, 38% less.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. McCoy Construction, Inc. averages $6,563 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

McCoy Construction, Inc.: OSHA citation items per year, 2009 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch McCoy Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347721235 OPENED AUG 29, 2024Closed

Referral · Partial · Safety · 5 employees at the site · Closed Mar 14, 2025

40 South Heathwood Drive, Marco Island, FL 34145 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346738388 OPENED JUN 1, 2023Closed

Referral · Partial · Safety · 3 employees at the site · Closed Dec 13, 2023

3551 Timarron Blvd Fairfield Hotel Project, Orlando, FL 32801 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(12) · Fall protection in construction
Serious$10,938$6,563Sep 25, 2023Final

Inspection 344838784 OPENED JUL 16, 2020Closed

Referral · Complete · Safety · 10 employees at the site · Closed Jan 6, 2021

144 Cypress Point Parkway, Palm Coast, FL 32164 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 16, 2020: Employee suffers multiple internal and external injuries aft

At 12:00 p.m. on July 13, 2020, Employee #1 was working for a structural steel contractor. Employee #1 was assisting with the process of installing roof panels. Employee #1 was standing on a lintel which was above a window. The lintel collapsed causing Employee #1 to fall landing on a pile of debris and is struck by a roofing panel. Employee #1 suffered multiple internal and external injuries. Employee #1 was hospitalized.

No citations from this inspection.

Inspection 313047631 OPENED FEB 5, 2009Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jan 1, 2016

2860 University Parkway, Sarasota, FL 34243 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$600$600Feb 17, 2009Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Aug 22, 2024, Marco Island: Hospitalization · fractures · multiple body parts n.e.c.

An employee was performing leading edge work when they fell 10-12 feet to the ground and sustained fractures to their L2 vertebra, left wrist, and both heels. The employee was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.501(b)(12)

(12) Precast concrete erection. Each employee engaged in the erection of precast concrete members (including, but not limited to the erection of wall panels, columns, beams, and floor and roof “tees”) and related operations such as grouting of precast concrete members, who is 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, or personal fall arrest systems, unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.