OSHA SearchOSHA records by employer

McCoy's Heating and Air, Inc.: OSHA inspections and violations

Jackson, Tennessee · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

4inspections
6citation items
$1,000current penalties
Jul 19, 2017last inspection

OSHA has inspected McCoy's Heating and Air, Inc. 4 times in Tennessee since 2004.

The latest one began on Jul 19, 2017 as a planned inspection, in Medina.

Those inspections ended with 6 citation items: 2 serious and 4 other-than-serious.

Penalties were first proposed at $1,300 and now stand at $1,000, 23% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and McCoy's Heating and Air, Inc. averages $0 (1 cited inspection).

McCoy's Heating and Air, Inc. also files yearly injury logs with OSHA, summarized below.

McCoy's Heating and Air, Inc.: OSHA citation items per year, 2004 to 2017
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

321employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch McCoy's Heating and Air, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342485562 OPENED JUL 19, 2017Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 17, 2017

100 Mt. Zion Road, Medina, TN 38355 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Aug 8, 2017Final
Citation 1, item 2
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Aug 8, 2017Final

Inspection 311143424 OPENED MAY 24, 2007Closed

Planned · Complete · Safety · 5 employees at the site · Closed Aug 6, 2007

1165 Vann Drive, Jackson, TN 38305 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$100$100Jun 11, 2007Closed

Inspection 309223857 OPENED JUL 8, 2005Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 23, 2005

201 West Chester Street, Jackson, TN 38301 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,200$900Aug 17, 2005Closed
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 17, 2005Closed

Inspection 307210104 OPENED MAR 12, 2004Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jan 5, 2005

230 D Street, Jackson, TN 38301 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0May 27, 2004Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Jackson site logged 3 recordable injuries or illnesses among about 70 workers: 5.1 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 61 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
McCoy's Heating & Air, Inc.
Jackson · 2024
70 315.11.8
McCoy's Heating & Air
Jackson · 2023
63 000.01.8
McCoy's Heating & Air Inc.
Jackson · 2019
65 101.51.8

Included with any plan: 4 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other plumbing, heating, and air-conditioning contractors employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.