Inspection 346623127 OPENED APR 6, 2023Closed
109-15 S. 24th Street, Philadelphia, PA 19103 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Philadelphia, Pennsylvania · Masonry Contractors · NAICS 238140
Since 2018, OSHA inspectors have visited MCH Masonry Group Inc. in Pennsylvania 3 times.
The most recent inspection opened on Apr 6, 2023 as part of a related case, in Philadelphia.
In all, OSHA issued 5 citation items: 4 serious and 1 repeat.
The proposed penalties came to $12,750; today they stand at $8,925, 30% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. MCH Masonry Group Inc. averages $8,925 across 1 cited inspection.
Pennsylvania · latest 90 days of OSHA records
277employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch MCH Masonry Group Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company109-15 S. 24th Street, Philadelphia, PA 19103 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1309 Cambridge St, Philadelphia, PA 19123 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2940 W Thompson Street, Philadelphia, PA 19121 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(1) · Scaffolds, general requirements |
Serious | $2,772 | $1,940 | Apr 19, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $2,772 | $1,940 | Apr 19, 2018 | Final |
| Citation 1, item 3a 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $3,880 | $2,716 | Apr 19, 2018 | Final |
| Citation 1, item 3b 29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements |
Serious | $0 | $0 | Apr 19, 2018 | Final |
| Citation 2, item 1 29 CFR 1926.454(a) · Scaffold training |
Repeat | $3,326 | $2,328 | Apr 19, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(c)(1)
(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(g)(1)(v)
(v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 9 1/2 inches (24.1 cm) of and along at least one side of the walkway.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.