McMinnville Electric System - Garage: OSHA inspections and violations

Mcminnville, Tennessee · Landscaping Services · NAICS 561730

1inspections
2citation items
$0current penalties
Nov 18, 2025last inspection

OSHA inspectors have visited McMinnville Electric System - Garage in Tennessee one time.

It opened on Nov 18, 2025 as a planned inspection, in Mcminnville.

In all, OSHA issued 2 citation items: 2 serious.

No penalty came with these citations.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,232 penalty. McMinnville Electric System - Garage averages $0 across 1 cited inspection.

McMinnville Electric System - Garage: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

321employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch McMinnville Electric System - Garage and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348601931 OPENED NOV 18, 2025Closed

Planned · Complete · Safety · Local government · 4 employees at the site · Closed Dec 2, 2025

200 West Morford Street, Mcminnville, TN 37110 · Landscaping Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Nov 24, 2025Final
Citation 1, item 2
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Nov 24, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.