OSHA SearchOSHA records by employer

Mechanical Service Solutions Corporation: OSHA inspections and violations

Virginia Beach, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
13citation items
$10,318current penalties
Sep 16, 2020last inspection

Since 2019, OSHA inspectors have visited Mechanical Service Solutions Corporation in Virginia 3 times.

The most recent inspection opened on Sep 16, 2020 as a planned inspection, in Virginia Beach.

In all, OSHA issued 13 citation items: 12 serious and 1 repeat.

The proposed penalties came to $14,740; today they stand at $10,318, 30% less.

The rule cited most here is 1926.405 (job-site wiring), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mechanical Service Solutions Corporation averages $3,439 across 3 cited inspections.

Mechanical Service Solutions Corporation: OSHA citation items per year, 2019 to 2020
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Mechanical Service Solutions Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344930284 OPENED SEP 16, 2020Closed

Planned · Complete · Safety · 20 employees at the site · Closed Jul 10, 2024

2800 Shore Drive, Virginia Beach, VA 23455 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.56(a) · Illumination
Serious$2,805$1,964Jan 7, 2021Final
Citation 1, item 2a
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$2,805$1,964Jan 7, 2021Final
Citation 1, item 2b
29 CFR 1926.403(i)(1)(ii) · Electrical equipment on job sites
Serious$0$0Jan 7, 2021Final
Citation 1, item 2c
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$0$0Jan 7, 2021Final
Citation 1, item 2d
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$0$0Jan 7, 2021Final
Citation 1, item 2e
29 CFR 1926.405(j)(1)(ii) · Job-site wiring
Serious$0$0Jan 7, 2021Final
Citation 1, item 2f
29 CFR 1926.417(b) · Lockout and tagging of circuits
Serious$0$0Jan 7, 2021Final
Citation 2, item 1
29 CFR 1926.405(d) · Job-site wiring
Repeat$6,730$4,711Jan 7, 2021Final

Inspection 344609359 OPENED JAN 23, 2020Closed

Planned · Complete · Safety · 23 employees at the site · Closed Jun 11, 2020

235 E Main Street, Norfolk, VA 23510 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Serious$600$420Mar 20, 2020Final
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$420Mar 20, 2020Final
Citation 1, item 3
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$600$420Mar 20, 2020Final

Inspection 344449640 OPENED NOV 15, 2019Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Mar 16, 2020

2800 Shore Drive, Virginia Beach, VA 23455 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(d) · Job-site wiring
Serious$600$420Jan 15, 2020Final
Citation 1, item 1b
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Jan 15, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.403(i)(1)(ii)

(ii) Clear spaces. Working space required by this subpart shall not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be guarded.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.417 · Lockout and tagging of circuits

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.56 · Illumination

Other electrical contractors and other wiring installation contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.