OSHA SearchOSHA records by employer

Medina's Plaster LLC: OSHA inspections and violations

Baton Rouge, Louisiana · Masonry Contractors · NAICS 238140

5inspections
11citation items
$9,316current penalties
Nov 19, 2020last inspection

Since 2007, OSHA inspectors have visited Medina's Plaster LLC in Louisiana 5 times.

The most recent inspection opened on Nov 19, 2020 as a planned inspection, in Metairie.

In all, OSHA issued 11 citation items: 9 serious and 2 other-than-serious.

The proposed penalties came to $22,244; today they stand at $9,316, 58% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Medina's Plaster LLC averages $3,108 across 2 cited inspections.

Medina's Plaster LLC: OSHA citation items per year, 2007 to 2020
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

19employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Medina's Plaster LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345033567 OPENED NOV 19, 2020Closed

Planned · Partial · Safety · 7 employees at the site · Closed Apr 27, 2021

6930 Veterans Blvd., Metairie, LA 70003 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$2,313$500Nov 27, 2020Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$2,892$500Nov 27, 2020Final

Inspection 342250206 OPENED APR 11, 2017Closed

Planned · Partial · Safety · 15 employees at the site · Closed Apr 14, 2017

135 Brocken Braugh Ct., Metairie, LA 70005 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342210101 OPENED MAR 24, 2017Closed

Planned · Partial · Safety · 8 employees at the site · Closed Feb 12, 2018

1200 W. Causeway Approach, Mandeville, LA 70471 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,803$1,521Apr 27, 2017Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,803$1,521Apr 27, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,803$1,521Apr 27, 2017Final
Citation 1, item 4
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$1,630$652Apr 27, 2017Final

Inspection 313022899 OPENED APR 16, 2009Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 15, 2010

4646 Constitution, Baton Rouge, LA 70808 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,500$1,050Aug 26, 2009Closed
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,500$1,050Aug 26, 2009Closed

Inspection 310254396 OPENED NOV 7, 2007Closed

Planned · Complete · Safety · 2 employees at the site · Closed Feb 20, 2008

13635 Stone Gate Dr., Baton Rouge, LA 70815 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,000$1,000Jan 30, 2008Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jan 30, 2008Closed
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jan 30, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.453 · Aerial lifts

Other masonry contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.