OSHA SearchOSHA records by employer

Meinke Custom Woodshop: OSHA inspections and violations

Fort Myers Beach, Florida · Finish Carpentry Contractors · NAICS 238350

1inspections
1citation items
$11,270current penalties
Jan 17, 2019last inspection

OSHA inspectors have visited Meinke Custom Woodshop in Florida one time.

It opened on Jan 17, 2019 after a fatality or catastrophe, in Fort Myers Beach.

In all, OSHA issued 1 citation item: 1 serious.

The proposed penalties came to $13,260; today they stand at $11,270, 15% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Meinke Custom Woodshop averages $11,270 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Meinke Custom Woodshop: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Meinke Custom Woodshop and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343722922 OPENED JAN 17, 2019Closed

Fatality or catastrophe · Complete · Safety · 2 employees at the site · Closed Aug 8, 2019

17305 Pine Ridge Rd, Fort Myers Beach, FL 33931 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 16, 2019 (fatal): Employee is using homemade wood burner and is electrocuted

At 11:00 p.m. on January 16, 2019, an employee was using a fractal Lichtenberg wood burning technique that applied a strong electrical current that burns and fractures a piece of wood that had been soaked with mineral water. The employee was electrocuted when he came into contact with an energized portion of the equipment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(a) · Electrical equipment, general requirements
Serious$13,260$11,270Jun 25, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(a)

(a) Approval. The conductors and equipment required or permitted by this subpart shall be acceptable only if approved, as defined in § 1910.399.

Other finish carpentry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.