Melton Heating & Air Conditioning Inc: OSHA inspections and violations

Salem, Oregon · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

4inspections
8citation items
$1,870current penalties
Jan 16, 2019last inspection

Since 2003, OSHA inspectors have visited Melton Heating & Air Conditioning Inc in Oregon 4 times.

The most recent inspection opened on Jan 16, 2019 on a referral, in Salem.

In all, OSHA issued 8 citation items: 5 serious and 3 other-than-serious.

The proposed penalties came to $2,870; today they stand at $1,870, 35% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Melton Heating & Air Conditioning Inc averages $590 across 3 cited inspections.

Melton Heating & Air Conditioning Inc: OSHA citation items per year, 2003 to 2019
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

383employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Melton Heating & Air Conditioning Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343729240 OPENED JAN 16, 2019Closed

Referral · Partial · Safety · 3 employees at the site · Closed Sep 12, 2019

649-653 High St, Salem, OR 97301 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-003-1501(1)
Serious$2,400$1,400Mar 13, 2019Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$120$120Mar 13, 2019Final

Inspection 341307197 OPENED MAR 8, 2016Closed

Planned · Partial · Safety · 13 employees at the site · Closed Aug 16, 2016

725 Hoyt St Se, Salem, OR 97302 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR OAR 437-002-2253(5)(B)(A)-2
Serious$150$150Apr 6, 2016Final
Citation 1, item 1b
29 CFR OAR 437-002-2253(5)(A)(D)
Serious$0$0Apr 6, 2016Final
Citation 2, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Apr 6, 2016Final

Inspection 341304475 OPENED MAR 3, 2016Closed

Planned · Complete · Safety · 13 employees at the site · Closed Aug 16, 2016

2060 Davcor St Se, Salem, OR 97302 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$100$100Mar 29, 2016Final
Citation 2, item 2
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Mar 29, 2016Final

Inspection 306466491 OPENED SEP 19, 2003Closed

Complaint · Partial · Safety · 12 employees at the site · Closed May 17, 2004

2060 Davcor St Se, Salem, OR 97302 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$100$100Oct 10, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(a)(2)

(2) Polarity of connections. No grounded conductor may be attached to any terminal or lead so as to reverse designated polarity.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.