OSHA SearchOSHA records by employer

Memo Services: OSHA inspections and violations

Mount Joy, Pennsylvania · Siding Contractors · NAICS 238170

1inspections
5citation items
$9,324current penalties
May 5, 2022last inspection

OSHA has inspected Memo Services once in Pennsylvania.

The inspection began on May 5, 2022 after a complaint, in Mount Joy.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $9,324 and still stand at $9,324.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Memo Services averages $9,324 (1 cited inspection).

Memo Services: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Memo Services again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345940902 OPENED MAY 5, 2022Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Dec 17, 2025

240 West Main Street, Mount Joy, PA 17552 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,108$3,108Sep 26, 2022Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$3,108$3,108Sep 26, 2022Final
Citation 1, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 26, 2022Final
Citation 1, item 3a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,108$3,108Sep 26, 2022Final
Citation 1, item 3b
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Sep 26, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other siding contractors employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.