OSHA SearchOSHA records by employer

Mericle Mechanical, Inc.: OSHA inspections and violations

Placentia, California · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

5inspections
9citation items
$37,810current penalties
Aug 12, 2020last inspection

Mericle Mechanical, Inc. has 5 OSHA inspections on record in California, the first in 2009.

OSHA's last visit started on Aug 12, 2020 after an accident, in Placentia.

Across those inspections OSHA issued 9 citation items: 2 serious and 7 other-than-serious.

OSHA proposed $58,275 in penalties. After settlements and reviews the total is $37,810, down 35%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mericle Mechanical, Inc. averages $33,200 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Mericle Mechanical, Inc.: OSHA citation items per year, 2009 to 2020
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,128employers cited

18 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Mericle Mechanical, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344877154 OPENED AUG 12, 2020Closed

Accident · Partial · Safety · 42 employees at the site · Closed Jun 26, 2023

1664 Sierra Madre Circle, Placentia, CA 92870 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 22, 2020: Two employee incurs burns to eyes and shoulder during coales

At 11:30 a.m. on July 22, 2020, two contractor's employees were assigned to perform coalesce filter replacement on compressor #2 (GEA GLX series screw compressor). During the process, anhydrous ammonia splashed onto their faces, eyes, and shoulders, causing burns to their eyes and shoulders. Both employees were treated for their injuries without hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 5144(E)(1)
Other-than-serious$275$2,500Nov 12, 2020Final
Citation 1, item 3
29 CFR 5189(H)(3)
Other-than-serious$515$2,500Nov 12, 2020Final
Citation 2, item 1
29 CFR 3203(A)(4)
Serious$12,375$25,000Nov 12, 2020Final
Citation 3, item 1
29 CFR 3203(A)(7)
Other-than-serious$12,375$1,600Nov 12, 2020Final
Citation 4, item 1
29 CFR 3328(H)
Other-than-serious$12,375$1,600Nov 12, 2020Final

Inspection 340718915 OPENED JUN 18, 2015Closed

Unprogrammed other · Partial · Safety · 38 employees at the site · Closed Oct 28, 2015

1664 Sierra Madre Circle Placentia, Placentia, CA 92870 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313647216 OPENED AUG 24, 2012Closed

Planned · Partial · Safety · 30 employees at the site · Closed Nov 18, 2013

16664 Sierra Madre Circle, Placentia, CA 92870 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314828971 OPENED APR 3, 2012Closed

Accident · Partial · Safety · 23 employees at the site · Closed Jul 26, 2014

4193 Industrial Parkway Dr., Lebec, CA 93243 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 3, 2012 (fatal): Worker falls through skylight and is killed

At approximately 6:00 p.m. on April 3, 2012, Employee #1 was working for a plumb ing, heating, and air conditioning contractor. The incident occurred at a retail store distribution warehouse. Employee #1 was a full-time permanent employee of the employer. He was not an employee of the retail distribution center. Employe e #1 was conducting the startup procedures for a roof-mounted condenser unit. He was on the west side of the condenser unit. The condenser unit was 89 inches (2 .26 meters) east of a skylight that was covered with acrylic plastic such as Ple xiglas. According to a witness, Employee #1 was facing east and talking on his c ell phone. He stood up and took a step or two backwards. He then appeared to stu mble or trip on his foot and fall backwards onto the skylight, breaking the acry lic plastic or Plexiglas cover. He fell approximately 39 feet (11.9 meters) to t he concrete floor below. Employee #1 received blunt force trauma injuries to mul tiple parts of his body, and he was killed. The causal factors were that employe e #1 was not wearing a fall protection device that was appropriately secured, an d that the skylight was not guarded or protected.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 3395 F01
Other-than-serious$335$0Aug 20, 2012Final
Citation 2, item 1
29 CFR 1509 A
Other-than-serious$4,050$335Aug 20, 2012Final
Citation 3, item 1
29 CFR 3212 E
Serious$15,750$4,050Aug 20, 2012Final

Inspection 312662265 OPENED OCT 8, 2009Closed

Complaint · Partial · Safety · 18 employees at the site · Closed Mar 31, 2010

707 N Barranca, Covina, CA 91723 · Engineering Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3395 E03
Other-than-serious$225$225Jan 22, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

Other plumbing, heating, and air-conditioning contractors employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.