OSHA SearchOSHA records by employer

Meritage Management Company LLC: OSHA inspections and violations

Bill, Wyoming · Pipeline Transportation of Natural Gas · NAICS 486210

1inspections
3citation items
$18,108current penalties
Jun 13, 2019last inspection

OSHA has inspected Meritage Management Company LLC once in Wyoming.

The inspection began on Jun 13, 2019 after a fatality or catastrophe, in Bill.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $27,162 and now stand at $18,108, 33% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for transportation and warehousing employers since 2015 is $2,424, and Meritage Management Company LLC averages $18,108 (1 cited inspection).

Meritage Management Company LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Meritage Management Company LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344080627 OPENED JUN 13, 2019Closed

Fatality or catastrophe · Partial · Safety · 100 employees at the site · Closed Apr 28, 2020

Sec 26, T39n, R72w, Bill, WY 82631 · Pipeline Transportation of Natural Gas · OSHA's record · Phone and website on Google Maps

Incident on Jun 12, 2019: Two employees sustain burns from flash fire

At approximately 2:30 p.m. on June 12, 2019, Employee #1 and Employee #2 were changing a dump valve on a water separation vessel on a natural gas compressor system. When the port was opened, the condensate spilled out leaking on the floor. Employee #1 and Employee #2 started opening doors and Employee #1 went to open a window when the vapors ignited. Both employees sustained burns to the upper body and arms. The employees were hospitalized for these burns.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 27-11-105 (B)(VI)(A)
Serious$9,054$9,054Dec 5, 2019Final
Citation 1, item 2
29 CFR 27-11-105 (B)(VI)(A)
Serious$9,054$0Dec 5, 2019Final
Citation 1, item 3a
29 CFR 1910.147(d)(5)(i) · Lockout/tagout
Serious$9,054$9,054Dec 5, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(d)(5)(i)

(5) Stored energy. (i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.