OSHA SearchOSHA records by employer

Merrimack Drywall Inc: OSHA inspections and violations

South Burlington, Vermont · Drywall and Insulation Contractors · NAICS 238310

3inspections
6citation items
$3,100current penalties
Jan 19, 2016last inspection

Since 2014, OSHA inspectors have visited Merrimack Drywall Inc in Vermont 3 times.

The most recent inspection opened on Jan 19, 2016 as a planned inspection, in South Burlington.

In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

The proposed penalties came to $9,425; today they stand at $3,100, 67% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Merrimack Drywall Inc averages $300 across 1 cited inspection.

Merrimack Drywall Inc: OSHA citation items per year, 2014 to 2016
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

24employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Merrimack Drywall Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341185569 OPENED JAN 19, 2016Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 17, 2016

465 Quarry Hill Rd, South Burlington, VT 05403 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341199990 OPENED JAN 19, 2016Closed

Planned · Complete · Health · 6 employees at the site · Closed Jun 1, 2016

465 Quarry Hill Rd, South Burlington, VT 05403 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$625$300Apr 26, 2016Final

Inspection 316748532 OPENED MAR 28, 2014Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jun 20, 2014

135 Depot Street, Manchester Center, VT 05255 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,000$2,000May 21, 2014Closed
Citation 1, item 3
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,000$0May 21, 2014Closed
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,000$0May 21, 2014Closed
Citation 1, item 5
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$2,000$0May 21, 2014Closed
Citation 1, item 6
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$800$800May 21, 2014Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.452 · Rules for each type of scaffold

Other drywall and insulation contractors employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.