OSHA SearchOSHA records by employer

Mestas Roofing, Inc.: OSHA inspections and violations

Las Vegas, Nevada · Roofing Contractors · NAICS 238160

15inspections
30citation items
$13,170current penalties
Mar 16, 2015last inspection

Mestas Roofing, Inc. has 15 OSHA inspections on record in Nevada, the first in 1984.

OSHA's last visit started on Mar 16, 2015 after a complaint, in Las Vegas.

Across those inspections OSHA issued 30 citation items: 18 serious and 12 other-than-serious.

OSHA proposed $22,700 in penalties. After settlements and reviews the total is $13,170, down 42%.

Most often, OSHA cited 1926.1101, asbestos in construction (8 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mestas Roofing, Inc. averages $5,220 over 1 cited inspection in that time.

Mestas Roofing, Inc.: OSHA citation items per year, 1984 to 2015
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

114employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Mestas Roofing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340465665 OPENED MAR 16, 2015Closed

Complaint · Partial · Health · 4 employees at the site · Closed Aug 5, 2015

953 East Sahara Avenue Suite B25, Las Vegas, NV 89109 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1101(e)(1) · Asbestos in construction
Serious$1,200$720May 27, 2015Final
Citation 1, item 2
29 CFR 1926.1101(e)(6) · Asbestos in construction
Serious$1,200$720May 27, 2015Final
Citation 1, item 3
29 CFR 1926.1101(g)(1)(ii) · Asbestos in construction
Serious$1,200$720May 27, 2015Final
Citation 1, item 4a
29 CFR 1926.1101(h)(1)(ii) · Asbestos in construction
Serious$1,200$720May 27, 2015Final
Citation 1, item 4b
29 CFR 1926.1101(h)(3)(i)(a) · Asbestos in construction
Serious$0$0May 27, 2015Final
Citation 1, item 5
29 CFR 1926.1101(k)(3)(i) · Asbestos in construction
Serious$1,200$720May 27, 2015Final
Citation 1, item 6
29 CFR 1926.1101(k)(9)(iii) · Asbestos in construction
Serious$1,200$720May 27, 2015Final
Citation 1, item 7
29 CFR 1926.1101(l)(2) · Asbestos in construction
Serious$1,200$720May 27, 2015Final
Citation 2, item 1
29 CFR NEVADA REVISED STATUTES 618.790
Other-than-serious$300$180May 27, 2015Final

Inspection 316001544 OPENED MAR 27, 2012Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 26, 2012

4845 Santa Barbara Street, Las Vegas, NV 89121 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312901473 OPENED MAR 18, 2009Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jun 16, 2009

8610 South Maryland Parkway, Las Vegas, NV 89123 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$2,000$2,000Apr 20, 2009Final
Citation 1, item 1b
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$2,000$0Apr 20, 2009Final
Citation 1, item 1c
29 CFR 1926.502(d)(17) · Fall protection systems
Serious$0$0Apr 20, 2009Final
Citation 1, item 1d
29 CFR 1926.502(d)(21) · Fall protection systems
Serious$0$0Apr 20, 2009Final
Citation 1, item 2
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$2,000$2,000Apr 20, 2009Final
Citation 2, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$2,000$400Apr 20, 2009Final

Inspection 311021851 OPENED OCT 11, 2007Closed

Referral · Partial · Safety · 50 employees at the site · Closed Nov 26, 2007

5600 East Russell Road, Las Vegas, NV 89120 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310431895 OPENED MAR 19, 2007Closed

Planned · Complete · Safety · 20 employees at the site · Closed Jun 20, 2007

2655 East Deer Springs Way, North Las Vegas, NV 89086 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,250$1,250Apr 24, 2007Closed
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Apr 11, 2007Closed

Inspection 307587816 OPENED JUL 1, 2004Closed

Unprogrammed related · Partial · Safety · 50 employees at the site · Closed Oct 11, 2004

7325 Savannah Falls Street, Las Vegas, NV 89131 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$500$300Jul 27, 2004Closed
Citation 2, item 1 Other-than-serious$0$0Jul 16, 2004Closed

Inspection 307587824 OPENED JUL 1, 2004Closed

Referral · Partial · Safety · 35 employees at the site · Closed Aug 30, 2004

7325 Savannah Falls Street, Las Vegas, NV 89131 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$500$500Jul 26, 2004Closed
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0Jul 21, 2004Closed

Inspection 307587600 OPENED JUN 23, 2004Closed

Referral · No inspection · Safety · Closed Jun 23, 2004

Alexander/martin Luther King, Las Vegas, NV 89102 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

7 older inspections

Inspection 307585638 OPENED MAY 14, 2004Closed

Referral · No inspection · Safety · Closed May 17, 2004

4800 Severance Lane, Las Vegas, NV 89131 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305459307 OPENED JUL 2, 2002Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jul 30, 2002

Stephanie/wigwam, Henderson, NV 89015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Jul 18, 2002Closed

Inspection 303962922 OPENED OCT 24, 2000Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Jan 9, 2001

142 Samantha Rose Street (sanoma Homes), Henderson, NV 89014 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,500$1,500Nov 27, 2000Closed
Citation 1, item 1b
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,250$0Nov 27, 2000Closed

Inspection 124736356 OPENED JAN 20, 1995Closed

Unprogrammed related · Complete · Safety · 20 employees at the site · Closed Jan 23, 1995

4091 East Owens, Las Vegas, NV 89115 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104686522 OPENED DEC 14, 1988Closed

Planned · Complete · Safety · 10 employees at the site · Closed Dec 15, 1988

4091 East Owens, Las Vegas, NV 89115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.169(b)(3)(i) · Air receivers
Other-than-serious$0$0Dec 15, 1988Closed
Citation 1, item 2
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Dec 15, 1988Closed
Citation 1, item 3
29 CFR 1926.602(c)(1)(iv) · Earthmovers and forklifts in construction
Other-than-serious$0$0Dec 15, 1988Closed
Citation 1, item 4
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Dec 15, 1988Closed
Citation 1, item 5
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0Dec 15, 1988Closed

Inspection 104627021 OPENED AUG 6, 1986Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 12, 1986

69 Reyburn Rd, Henderson, NV 89015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.169(b)(3)(i) · Air receivers
Other-than-serious$0$0Aug 7, 1986Closed

Inspection 14955371 OPENED DEC 3, 1984Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 4, 1984

1751 E Reno Av, Las Vegas, NV 89119 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.169 · Air receivers

29 CFR 1910.169(b)(3)(i)

(3) Gages and valves. (i) Every air receiver shall be equipped with an indicating pressure gage (so located as to be readily visible) and with one or more spring-loaded safety valves. The total relieving capacity of such safety valves shall be such as to prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.25 · Housekeeping

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 6180.3750

29 CFR 6180.3830

Other roofing contractors employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.