OSHA SearchOSHA records by employer

Metpar Corporation: OSHA inspections and violations

Tampa, Florida · Showcase, Partition, Shelving, and Locker Manufacturing · NAICS 337215

1inspections
7citation items
$30,325current penalties
Mar 20, 2024last inspection

OSHA has inspected Metpar Corporation once in Florida.

The inspection began on Mar 20, 2024 after a complaint, in Tampa.

That inspection ended with 7 citation items: 7 serious.

Penalties were first proposed at $43,322 and now stand at $30,325, 30% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Metpar Corporation averages $30,325 (1 cited inspection).

Metpar Corporation: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Metpar Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347366973 OPENED MAR 20, 2024Closed

Complaint · Partial · Safety · 13 employees at the site · Closed May 28, 2026

7211 Anderson Rd, Tampa, FL 33614 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$6,452$4,516May 21, 2024Final
Citation 1, item 2
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$6,452$4,516May 21, 2024Final
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$6,452$4,516May 21, 2024Final
Citation 1, item 4
29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements
Serious$6,452$4,516May 21, 2024Final
Citation 1, item 5
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$6,452$4,516May 21, 2024Final
Citation 1, item 6
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$6,452$4,516May 21, 2024Final
Citation 1, item 7
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$4,610$3,227May 21, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other showcase, partition, shelving, and locker manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.