Metro Electric, Inc.: OSHA inspections and violations
Sioux City, Iowa · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
5inspections
5citation items
$2,501current penalties
Oct 16, 2023last inspection
Metro Electric, Inc. has 5 OSHA inspections on record in Iowa, the first in 2005.
OSHA's last visit started on Oct 16, 2023, in Hawarden.
Across those inspections OSHA issued 5 citation items: 3 serious and 2 other-than-serious.
OSHA proposed $3,752 in penalties. After settlements and reviews the total is $2,501, down 33%.
Most often, OSHA cited 1926.405, job-site wiring (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Metro Electric, Inc. averages $813 over 2 cited inspections in that time.
Metro Electric, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Iowa · latest 90 days of OSHA records
64employers cited
Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Sioux City site logged 3 recordable injuries or illnesses among about 41 workers: 8.2 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 7 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Metro Electric, Inc.
Sioux City · 2025
41
3
1
8.2
1.8
Metro Electric Inc
Sioux City · 2019
37
2
1
5.6
1.8
Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(b) Implementation—(1) What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.
(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.
29 CFR 1926.405(d)
(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.
Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.