Inspection 342123106 OPENED FEB 22, 2017Closed
Academy St, Mexico, NY 13114 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Mexico Vill Pump Station #1 has 2 OSHA inspections on record in New York, the first in 2017.
OSHA's last visit started on Feb 22, 2017 to follow up on an earlier case, in Mexico.
Across those inspections OSHA issued 4 citation items: 4 serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1910.305, electrical wiring methods (3 items).
For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Mexico Vill Pump Station #1 averages $0 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
362employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Mexico Vill Pump Station #1 and get notified the morning OSHA posts a new citation for it.
Watch this companyAcademy St, Mexico, NY 13114 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Academy St, Mexico, NY 13114 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $0 | $0 | Feb 15, 2017 | Final |
| Citation 1, item 2 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Feb 15, 2017 | Final |
| Citation 1, item 3 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Feb 15, 2017 | Final |
| Citation 1, item 4 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Feb 15, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.305(b)(1)(ii)
(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.
29 CFR 1910.305(b)(2)(i)
(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
29 CFR 1910.305(g)(2)(iii)
(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.