MG Excellence Services Corp: OSHA inspections and violations

Miami, Florida · Roofing Contractors · NAICS 238160

2inspections
2citation items
$8,002current penalties
Nov 4, 2019last inspection

Since 2019, OSHA inspectors have visited MG Excellence Services Corp in Florida 2 times.

The most recent inspection opened on Nov 4, 2019 to follow up on an earlier case, in Miami.

In all, OSHA issued 2 citation items: 1 serious and 1 repeat.

The proposed penalties came to $13,336; today they stand at $8,002, 40% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. MG Excellence Services Corp averages $8,002 across 1 cited inspection.

MG Excellence Services Corp: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

70 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch MG Excellence Services Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344424825 OPENED NOV 4, 2019Closed

Follow-up · No inspection · Safety · 14 employees at the site · Closed Nov 12, 2019

5941 Sw 164 Ct, Miami, FL 33193 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344008487 OPENED MAY 14, 2019Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Nov 12, 2019

10290 Nw 9th Street Circle, Miami, FL 33172 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$5,001$3,001Jul 12, 2019Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$8,335$5,002Jul 12, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.