OSHA SearchOSHA records by employer

MGV Masonry, LLC: OSHA inspections and violations

Macon, Georgia · Masonry Contractors · NAICS 238140

1inspections
6citation items
$19,094current penalties
Jan 18, 2019last inspection

OSHA inspectors have visited MGV Masonry, LLC in Georgia one time.

It opened on Jan 18, 2019 on a referral, in Macon.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $31,824; today they stand at $19,094, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. MGV Masonry, LLC averages $19,094 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

MGV Masonry, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

145employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch MGV Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343725495 OPENED JAN 18, 2019Closed

Referral · Complete · Safety · 14 employees at the site · Closed Feb 22, 2021

1897 Allen Road, Macon, GA 31216 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 17, 2019: Employee falls and injures back when scaffold plank breaks

At 8:00 a.m. on January 17, 2019, Employee #1, employed by a masonry contractor, was working from the platform of a scaffold system at the multi-employer construction site for a new commercial building. The wood plank he was standing on cracked, and the employee fell. The employee was transported to the hospital, admitted, and treated for multiple injuries including injury to his back. Subsequent investigation revealed multiple problems with the scaffold system, including improper installation and overloading. overloading.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$5,304$3,182Apr 16, 2019Final
Citation 1, item 2
29 CFR 1926.451(b)(3)(i) · Scaffolds, general requirements
Serious$5,304$3,182Apr 16, 2019Final
Citation 1, item 3
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$5,304$3,182Apr 16, 2019Final
Citation 1, item 4
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$5,304$3,182Apr 16, 2019Final
Citation 1, item 5
29 CFR 1926.451(f)(1) · Scaffolds, general requirements
Serious$5,304$3,182Apr 16, 2019Final
Citation 1, item 6
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$5,304$3,182Apr 16, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 17, 2019, Macon: Hospitalization · fractures · multiple body parts, n.e.c.

An employee was putting bricks on an elevator when he fell from a scaffold, landing about 20-30 feet below. Blocks fell on top of him. He was hospitalized with a broken arm and broken back.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(3)(i)

(i) The maximum distance from the face for outrigger scaffolds shall be 3 inches (8 cm);

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

Other masonry contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.