OSHA SearchOSHA records by employer

Mic Construction Corp.: OSHA inspections and violations

Avenel, New Jersey · Masonry Contractors · NAICS 238140

3inspections
8citation items
$11,860current penalties
Jul 26, 2021last inspection

OSHA has inspected Mic Construction Corp. 3 times in New Jersey since 2015.

The latest one began on Jul 26, 2021 as a planned inspection, in Monroe Township.

Those inspections ended with 8 citation items: 8 serious.

Penalties were first proposed at $17,274 and now stand at $11,860, 31% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Mic Construction Corp. averages $3,953 (3 cited inspections).

Mic Construction Corp.: OSHA citation items per year, 2015 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Mic Construction Corp. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345438543 OPENED JUL 26, 2021Closed

Planned · Partial · Safety · 9 employees at the site · Closed Aug 3, 2023

15 Galerie Court Venue Blvd. - Gate House - Venue At Monroe, Monroe Township, NJ 08831 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,341$1,638Dec 15, 2021Final
Citation 1, item 1b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Dec 15, 2021Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,755$1,224Dec 15, 2021Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,341$1,638Dec 15, 2021Final

Inspection 345381693 OPENED JUN 25, 2021Closed

Planned · Partial · Safety · 10 employees at the site · Closed Aug 3, 2023

450 Springfield Ave., Berkeley Heights, NJ 07922 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,096$2,867Dec 9, 2021Final
Citation 1, item 2
29 CFR 1926.502(e)(2) · Fall protection systems
Serious$2,341$1,633Dec 9, 2021Final

Inspection 340745595 OPENED JUN 29, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 18, 2016

475 Avenel Street, Avenel, NJ 07001 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,600$1,040Aug 17, 2015Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,800$1,820Aug 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other masonry contractors employers in New Jersey

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.