OSHA SearchOSHA records by employer

Michael J Grant Etal: OSHA inspections and violations

Portland, Oregon · Lessors of Residential Buildings and Dwellings · NAICS 531110

1inspections
6citation items
$2,840current penalties
Feb 10, 2017last inspection

Michael J Grant Etal has one OSHA inspection on record in Oregon.

OSHA opened it on Feb 10, 2017 after a complaint, in Portland.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $2,840 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all real estate and rental employers the median penalty per cited inspection since 2015 is $1,857. Michael J Grant Etal averages $2,840 over 1 cited inspection in that time.

Michael J Grant Etal: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Michael J Grant Etal and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342100237 OPENED FEB 10, 2017Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Sep 27, 2017

4950 Sw Barbur Blvd, Portland, OR 97239 · Lessors of Residential Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$840$840Mar 30, 2017Final
Citation 1, item 2a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$200$200Mar 30, 2017Final
Citation 1, item 2b
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$0$0Mar 30, 2017Final
Citation 1, item 3
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$200$200Mar 30, 2017Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,400$1,400Mar 30, 2017Final
Citation 1, item 5
29 CFR OAR 437-001-0765(1)-3
Serious$200$200Mar 30, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(1)(ii)

(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.