OSHA SearchOSHA records by employer

Mid-State Mobile Concrete Inc: OSHA inspections and violations

Hermitage, Tennessee · Ready-Mix Concrete Manufacturing · NAICS 327320

1inspections
15citation items
$5,000current penalties
Jun 28, 2018last inspection

OSHA inspectors have visited Mid-State Mobile Concrete Inc in Tennessee one time.

It opened on Jun 28, 2018 as a planned inspection, in Hermitage.

In all, OSHA issued 15 citation items: 10 serious and 5 other-than-serious.

The penalties, $5,000 in total, stand where OSHA first set them.

The rule cited most here is 1910.157 (portable fire extinguishers), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Mid-State Mobile Concrete Inc averages $5,000 across 1 cited inspection.

Mid-State Mobile Concrete Inc: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

339employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Mid-State Mobile Concrete Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343259842 OPENED JUN 28, 2018Closed

Planned · Complete · Safety · 21 employees at the site · Closed Sep 20, 2018

3636 Central Pike, Hermitage, TN 37076 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(3) · Walking-working surfaces
Serious$700$700Aug 3, 2018Final
Citation 1, item 2
29 CFR 1910.28(b)(11)(iii) · Fall protection in general industry
Serious$700$700Aug 3, 2018Final
Citation 1, item 3
29 CFR 1910.36(d)(1) · Exit route design
Serious$500$500Aug 3, 2018Final
Citation 1, item 4
29 CFR 1910.37(a)(3) · Exit routes
Serious$500$500Aug 3, 2018Final
Citation 1, item 5
29 CFR 1910.212(a)(5) · Machine guarding
Serious$600$600Aug 3, 2018Final
Citation 1, item 6a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$600$600Aug 3, 2018Final
Citation 1, item 6b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Aug 3, 2018Final
Citation 1, item 7
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$400$400Aug 3, 2018Final
Citation 1, item 8
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$400$400Aug 3, 2018Final
Citation 1, item 9
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$600$600Aug 3, 2018Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Aug 3, 2018Final
Citation 2, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Aug 3, 2018Final
Citation 2, item 3
29 CFR 1910.157(e)(4) · Portable fire extinguishers
Other-than-serious$0$0Aug 3, 2018Final
Citation 2, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 3, 2018Final
Citation 2, item 5
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Other-than-serious$0$0Aug 3, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.157(e)(4)

(4) The employer shall assure that stored pressure dry chemical extinguishers that require a 12-year hydrostatic test are emptied and subjected to applicable maintenance procedures every 6 years. Dry chemical extinguishers having non-refillable disposable containers are exempt from this requirement. When recharging or hydrostatic testing is performed, the 6-year requirement begins from that date.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other ready-mix concrete manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.