OSHA SearchOSHA records by employer

Midwest Steel Inc: OSHA inspections and violations

Louisville, Kentucky · Structural Steel and Precast Concrete Contractors · NAICS 238120

6inspections
4citation items
$19,800current penalties
Sep 20, 2022last inspection

Midwest Steel Inc has 6 OSHA inspections on record in Kentucky, the first in 2004.

OSHA's last visit started on Sep 20, 2022 on a referral, in Louisville.

Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

OSHA proposed $19,800 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Midwest Steel Inc averages $6,300 over 1 cited inspection in that time.

Midwest Steel Inc: OSHA citation items per year, 2004 to 2022
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

190employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Midwest Steel Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346237464 OPENED SEP 20, 2022Closed

Referral · Partial · Safety · 52 employees at the site · Closed Mar 17, 2026

4521 Crittenden Dr, Louisville, KY 40209 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.756(a)(1) · Beams and columns
Other-than-serious$6,300$6,300Jan 24, 2023Final

Inspection 316917889 OPENED AUG 16, 2013Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Aug 16, 2013

6785 Houston Rd., Florence, KY 41042 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311300321 OPENED MAY 20, 2008Closed

Unprogrammed other · Partial · Safety · 600 employees at the site · Closed May 20, 2008

4021 John Henry Ln, Lexington, KY 40511 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311298970 OPENED APR 22, 2008Closed

Unprogrammed other · Complete · Safety · 25 employees at the site · Closed Apr 22, 2008

4021 John Henry Ln, Lexington, KY 40511 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308083245 OPENED SEP 27, 2004Closed

Unprogrammed other · Complete · Safety · 23 employees at the site · Closed Sep 27, 2004

Ky State Fair & Exposition Center Phillips Ln, Louisville, KY 40209 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307561803 OPENED AUG 17, 2004Closed

Unprogrammed related · Partial · Safety · 23 employees at the site · Closed Dec 15, 2012

937 Phillips Ln S Wing C, Louisville, KY 40209 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$4,500$4,500Sep 24, 2004Contested
Citation 1, item 2
29 CFR 1926.754(e)(5)(i) · Structural steel assembly
Serious$4,500$4,500Sep 24, 2004Contested
Citation 1, item 3 Serious$4,500$4,500Sep 24, 2004Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.754 · Structural steel assembly

29 CFR 1926.754(e)(5)(i)

(5) Installation of metal decking. (i) Except as provided in § 1926.760(c), metal decking shall be laid tightly and immediately secured upon placement to prevent accidental movement or displacement.

29 CFR 1926.756 · Beams and columns

29 CFR 1926.756(a)(1)

(a) General. (1) During the final placing of solid web structural members, the load shall not be released from the hoisting line until the members are secured with at least two bolts per connection, of the same size and strength as shown in the erection drawings, drawn up wrench-tight or the equivalent as specified by the project structural engineer of record, except as specified in paragraph (b) of this section.

29 CFR 1926.760 · Fall protection

29 CFR 1926.760(a)(1)

(a) General requirements. (1) Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.

29 CFR 1926.761 · Training

Other structural steel and precast concrete contractors employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.