OSHA SearchOSHA records by employer

Miguel Chaires: OSHA inspections and violations

Laredo, Texas · Framing Contractors · NAICS 238130

3inspections
11citation items
$10,471current penalties
Apr 16, 2019last inspection

Miguel Chaires has 3 OSHA inspections on record in Texas, the first in 2010.

OSHA's last visit started on Apr 16, 2019 as a planned inspection, in Laredo.

Across those inspections OSHA issued 11 citation items: 10 serious and 1 other-than-serious.

OSHA proposed $10,924 in penalties. After settlements and reviews the total is $10,471, down 4%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Miguel Chaires averages $2,592 over 1 cited inspection in that time.

Miguel Chaires: OSHA citation items per year, 2010 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

55 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Miguel Chaires and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343937298 OPENED APR 16, 2019Closed

Planned · Partial · Safety · 6 employees at the site · Closed Apr 15, 2024

10902 International Blvd, Laredo, TX 78045 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,273$2,273Jul 26, 2019Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$319$319Nov 4, 2019Final

Inspection 316301845 OPENED MAR 14, 2012Closed

Planned · Complete · Safety · 5 employees at the site · Closed Feb 11, 2016

3012 Swift, Laredo, TX 78041 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$1,800$1,800Sep 11, 2012Closed
Citation 1, item 2a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,800$1,800Sep 11, 2012Closed
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Sep 11, 2012Closed
Citation 1, item 3a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,800$1,800Sep 11, 2012Closed
Citation 1, item 3b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 11, 2012Closed
Citation 1, item 3c
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Sep 11, 2012Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,800$1,800Sep 11, 2012Closed

Inspection 314454653 OPENED JUN 15, 2010Closed

Planned · Partial · Safety · 12 employees at the site · Closed Jan 14, 2016

2620 Plantation, Laredo, TX 78041 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$750$450Jul 15, 2010Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$382$229Jul 15, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.