Inspection 347086670 OPENED NOV 2, 2023Closed
342 Water Ridge Dr, Lavon, TX 75166 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Miguel Valdivia has 9 OSHA inspections on record in Texas, the first in 2007.
OSHA's last visit started on Nov 2, 2023 to follow up on an earlier case, in Lavon.
Across those inspections OSHA issued 26 citation items: 21 serious and 5 repeat.
OSHA proposed $102,546 in penalties. After settlements and reviews the total is $62,492, down 39%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (19 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Miguel Valdivia averages $13,123 over 4 cited inspections in that time.
Texas · latest 90 days of OSHA records
393employers cited
13 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Miguel Valdivia and get notified the morning OSHA posts a new citation for it.
Watch this company342 Water Ridge Dr, Lavon, TX 75166 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
418 Oak Creek Dr, Lavon, TX 75166 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
319 Hidden Waters Drive, Lavon, TX 75166 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $4,018 | $4,018 | Jan 25, 2023 | Final |
| Citation 1, item 1b 29 CFR 1926.416(e)(1) · Electrical safety in construction |
Serious | $4,688 | $0 | Jan 25, 2023 | Final |
| Citation 1, item 1c 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $4,688 | $0 | Jan 25, 2023 | Final |
| Citation 1, item 1d 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $9,375 | $0 | Jan 25, 2023 | Final |
| Citation 1, item 1e 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $9,375 | $0 | Jan 25, 2023 | Final |
342 Water Ridge Dr, Lavon, TX 75166 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
342 Water Ridge Drive, Lavon, TX 75166 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
418 Oak Creek Dr, Lavon, TX 75166 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Repeat | $9,571 | $4,000 | Dec 2, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Repeat | $9,571 | $4,000 | Dec 2, 2022 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $4,786 | $4,000 | Dec 2, 2022 | Final |
5413 Basham Lane, Denton, TX 76207 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Oct 22, 2021 | Final |
| Citation 1, item 2 29 CFR 1926.451(b)(3) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Oct 22, 2021 | Final |
| Citation 1, item 3 29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Oct 22, 2021 | Final |
| Citation 1, item 4 29 CFR 1926.451(c)(3) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Oct 22, 2021 | Final |
| Citation 1, item 5 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Oct 22, 2021 | Final |
| Citation 1, item 6 29 CFR 1926.451(h)(2) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Oct 22, 2021 | Final |
| Citation 1, item 7 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $4,096 | $4,096 | Oct 22, 2021 | Final |
14094 Berryfield Lane, Frisco, TX 75034 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $3,901 | $3,901 | Sep 29, 2021 | Final |
| Citation 1, item 1b 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Sep 29, 2021 | Final |
| Citation 1, item 1c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Sep 29, 2021 | Final |
| Citation 1, item 2a 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $3,901 | $3,901 | Sep 29, 2021 | Final |
| Citation 1, item 2b 29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 29, 2021 | Final |
| Citation 1, item 2c 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 29, 2021 | Final |
| Citation 1, item 2d 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 29, 2021 | Final |
| Citation 1, item 2e 29 CFR 1926.451(h)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 29, 2021 | Final |
806 Chumley, Garland, TX 75044 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Repeat | $4,000 | $4,000 | Sep 27, 2007 | Closed |
| Citation 1, item 2 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Repeat | $4,000 | $4,000 | Sep 27, 2007 | Closed |
| Citation 1, item 3 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Repeat | $2,000 | $2,000 | Sep 27, 2007 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(g)(8)
(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)
29 CFR 1910.1200(h)(1)
(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.