OSHA SearchOSHA records by employer

Mike Garner Construction, Inc.: OSHA inspections and violations

Morgan, Utah · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
3citation items
$1,550current penalties
Nov 14, 2023last inspection

OSHA inspectors have visited Mike Garner Construction, Inc. in Utah one time.

It opened on Nov 14, 2023 after an accident, in Morgan.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $2,600; today they stand at $1,550, 40% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mike Garner Construction, Inc. averages $1,550 across 1 cited inspection.

Mike Garner Construction, Inc.: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Mike Garner Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347101750 OPENED NOV 14, 2023Closed

Accident · Partial · Safety · 4 employees at the site · Closed Jan 19, 2024

282 E 400 N, Morgan, UT 84050 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,100$1,050Dec 4, 2023Final
Citation 1, item 1b
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$0$0Dec 4, 2023Final
Citation 2, item 1
29 CFR UAC R614-1-5.B.1
Other-than-serious$500$500Dec 4, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other poured concrete foundation and structure contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.