Inspection 348677139 OPENED JAN 8, 2026Closed
6700 Md Anderson, Houston, TX 77030 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Milestone Metals, Inc. 12 times in Texas since 1992.
The latest one began on Jan 8, 2026 as a planned inspection, in Houston.
Those inspections ended with 11 citation items: 5 serious and 6 other-than-serious.
Penalties were first proposed at $10,607 and now stand at $6,134, 42% lower after settlements or reviews.
Hazard communication comes up most often in these citations: 4 items under 1926.59.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Milestone Metals, Inc. averages $5,734 (1 cited inspection).
Milestone Metals, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Texas · latest 90 days of OSHA records
398employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Milestone Metals, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company6700 Md Anderson, Houston, TX 77030 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6516 Md Anderson Blvd, Houston, TX 77054 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2601 Victory Ave, Dallas, TX 75219 · Iron and Steel Forging · OSHA's record · Phone and website on Google Maps
Incident on Dec 28, 2020: Scissor lift tips over due to falling steel column and injur
At 4:44 p.m. on December 28, 2024, two employees were working inside the basket of a Genie GS3232 scissor lift, installing ceiling supports consisting of 3,500-pound, 32-foot double channel steel columns in the lobby area. During the installation of the first column of the day, the employees were using a Strongway electric chain hoist and a Jet L-100 series hand chain hoist to lift the column, with assistance from a GEHL RS5-19 forklift. While the column was being positioned, it fell onto the scissor lift, causing the lift to tip over. Both employees sustained unspecified injuries and were hospitalized for treatment.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $9,557 | $5,734 | Apr 22, 2021 | Final |
| Citation 1, item 1b 29 CFR 1926.251(a)(2)(ii) · Rigging equipment for material handling |
Serious | $0 | $0 | Apr 22, 2021 | Final |
800 Young Street, Dallas, TX 75202 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3000 Grapevine Mills Pkwy., Grapevine, TX 76051 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3200 West 11th St, Hpuston, TX 77008 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1313 Lake Woodland Dr., The Woodlands, TX 77380 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7575 N. Sam Houston Pkwy W., Houston, TX 77252 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1300 San Jacinto St., Austin, TX 78701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.351(b)(4) · Arc welding and cutting |
Other-than-serious | $0 | $0 | Aug 26, 1993 | Closed |
14301 Katy Frwy., Houston, TX 77079 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1499 1/2 Congress Ave., Austin, TX 78704 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(b)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 5, 1992 | Closed |
| Citation 1, item 2 29 CFR 1910.134(e)(5)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 5, 1992 | Closed |
| Citation 1, item 3 29 CFR 1926.59(e)(1)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 5, 1992 | Closed |
| Citation 1, item 4 29 CFR 1926.59(e)(2) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 5, 1992 | Closed |
8212 Barton Club Dr., Austin, TX 78735 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.59(e)(1)(i) · Hazard communication |
Serious | $525 | $200 | Jun 23, 1992 | Final |
| Citation 1, item 1b 29 CFR 1926.59(e)(1)(ii) · Hazard communication |
Serious | $0 | $0 | Jun 23, 1992 | Final |
| Citation 1, item 3 29 CFR 1926.451(e)(5) · Scaffolds, general requirements |
Serious | $525 | $200 | Jun 23, 1992 | Final |
| Citation 2, item 1 29 CFR 1904.2(a) · Partial exemption for establishments in certain industries |
Other-than-serious | $0 | $0 | Jun 23, 1992 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2018, the Houston site logged 0 recordable injuries or illnesses among about 77 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Milestone Metals Houston · 2018 | 77 | 0 | 0 | 0.0 | 2.8 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Dec 28, 2020, Dallas: Hospitalization · fractures · nonclassifiable
Two employees were in a scissor lift while a 3,500-pound column was lifted into place to be welded. The column released from its chainfall and struck the scissor lift, tipping it over. One of the employees remained inside the lift while the second employee landed about 2 feet outside the lift. Both employees were hospitalized for fractures and sprains/strains. Both employees were wearing fall protection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(b)(1)
(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally for 1 minute. After the normal breathing exercise, the subject needs to hold head straight ahead and hold his or her breath for 10 seconds during the test measurement.
29 CFR 1910.134(e)(5)(i)
(5) Supplemental information for the PLHCP. (i) The following information must be provided to the PLHCP before the PLHCP makes a recommendation concerning an employee's ability to use a respirator:
29 CFR 1926.21(b)(2)
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.