OSHA SearchOSHA records by employer

Milford Electric: OSHA inspections and violations

Milford, Iowa · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
2citation items
$525current penalties
Aug 30, 2016last inspection

OSHA inspectors have visited Milford Electric in Iowa one time.

It opened on Aug 30, 2016, in Milford.

In all, OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

The proposed penalties came to $1,050; today they stand at $525, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Milford Electric averages $525 across 1 cited inspection.

Milford Electric: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

64employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Milford Electric and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341751170 OPENED AUG 30, 2016Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Dec 15, 2016

2246 220th St, Milford, IA 51351 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(b) · Job-site wiring
Serious$750$375Nov 22, 2016Final
Citation 2, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$300$150Nov 22, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(b)

(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.

Other electrical contractors and other wiring installation contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.