OSHA SearchOSHA records by employer

Milian & Son Carpentry LLC: OSHA inspections and violations

Fairfield, Connecticut · Framing Contractors · NAICS 238130

1inspections
5citation items
$5,674current penalties
Apr 10, 2026last inspection

OSHA inspectors have visited Milian & Son Carpentry LLC in Connecticut one time.

It opened on Apr 10, 2026 on a referral, in Fairfield and is still open.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $11,349; today they stand at $5,674, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Milian & Son Carpentry LLC averages $5,674 across 1 cited inspection.

Milian & Son Carpentry LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

88employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Milian & Son Carpentry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348869827 OPENED APR 10, 2026Open

Referral · Partial · Safety · 8 employees at the site · Open

17 Greenbrier Road, Fairfield, CT 06824 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$3,972$1,986Apr 30, 2026Final
Citation 1, item 1b
29 CFR 1926.451(f)(15)(ii) · Scaffolds, general requirements
Serious$0$0Apr 30, 2026Final
Citation 1, item 1c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Apr 30, 2026Final
Citation 1, item 4
29 CFR 1926.452(k)(2) · Rules for each type of scaffold
Serious$3,972$1,986Apr 30, 2026Final
Citation 1, item 5
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$3,405$1,702Apr 30, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)

(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(15)(ii)

(ii) The platform units shall be secured to the scaffold to prevent their movement;

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

Other framing contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.