OSHA SearchOSHA records by employer

Milne Brothers Roofing LLC: OSHA inspections and violations

West Valley City, Utah · Roofing Contractors · NAICS 238160

9inspections
17citation items
$37,200current penalties
Jan 24, 2020last inspection

OSHA has inspected Milne Brothers Roofing LLC 9 times in Utah since 1998.

The latest one began on Jan 24, 2020 as a planned inspection, in Lehi.

Those inspections ended with 17 citation items: 11 serious, 1 willful, 4 repeat and 1 other-than-serious.

Penalties were first proposed at $50,925 and now stand at $37,200, 27% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 9 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Milne Brothers Roofing LLC averages $11,625 (2 cited inspections).

Milne Brothers Roofing LLC: OSHA citation items per year, 1998 to 2020
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

73employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Milne Brothers Roofing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344578430 OPENED JAN 24, 2020Closed

Planned · Partial · Safety · 12 employees at the site · Closed Nov 18, 2020

2700 N. 4340 W. Heston Park St., Lehi, UT 84043 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Willful$21,000$21,000Mar 5, 2020Final
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$1,500Mar 5, 2020Final
Citation 3, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Mar 5, 2020Final

Inspection 340660653 OPENED MAY 19, 2015Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 14, 2015

6150 W 4080 S, West Valley City, UT 84119 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,500$750Jul 8, 2015Final
Citation 1, item 1b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Jul 8, 2015Final

Inspection 314196031 OPENED JUL 29, 2011Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jun 26, 2012

Lot B5 Herriman Towne Center, Holladay, UT 84065 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$10,000$2,400Aug 15, 2011Closed

Inspection 312410285 OPENED JUL 27, 2009Closed

Planned · Partial · Safety · 3 employees at the site · Closed Mar 1, 2010

Thanksgiving Meadows Lot-105, Lehi, UT 84043 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$4,000$2,000Aug 17, 2009Closed
Citation 2, item 1
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$1,500$750Aug 17, 2009Closed

Inspection 312409196 OPENED MAY 13, 2009Closed

Planned · Partial · Safety · 6 employees at the site · Closed Aug 10, 2009

6135 W 5780 S South Ridge Lot 130, Kearns, UT 84118 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$2,800$800Jun 16, 2009Closed

Inspection 309171502 OPENED AUG 28, 2006Closed

Planned · Partial · Safety · 8 employees at the site · Closed Dec 21, 2006

3315 West 12600 South, Riverton, UT 84065 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,000$2,000Nov 21, 2006Closed
Citation 1, item 1b
29 CFR 1926.502(a)(2) · Fall protection systems
Serious$0$0Nov 21, 2006Closed

Inspection 305401671 OPENED DEC 18, 2003Closed

Referral · Complete · Safety · 5 employees at the site · Closed Nov 15, 2004

Se Of 5570 W. 13940 S., Riverton, UT 84065 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$625$312Feb 11, 2004Closed
Citation 1, item 2
29 CFR 1926.503(c) · Fall protection training in construction
Serious$625$312Feb 11, 2004Closed

Inspection 126795392 OPENED NOV 10, 1998Closed

Planned · Complete · Safety · 5 employees at the site · Closed Nov 11, 1999

3780 W. 2975 S., West Valley City, UT 84120 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$2,125$2,125Nov 23, 1998Closed
Citation 2, item 1a
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$1,875$1,875Nov 23, 1998Closed
Citation 2, item 1b
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$0$0Nov 23, 1998Closed
1 older inspection

Inspection 126786730 OPENED APR 14, 1998Closed

Planned · Complete · Safety · 6 employees at the site · Closed Apr 15, 1999

4660 W Black Elk Way, West Jordan, UT 84088 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,375$1,375Apr 20, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.