OSHA SearchOSHA records by employer

Mission Drywall and Ceiling, LLC: OSHA inspections and violations

Baltimore, Maryland · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
5citation items
$1,749current penalties
Feb 24, 2017last inspection

OSHA has inspected Mission Drywall and Ceiling, LLC once in Maryland.

The inspection began on Feb 24, 2017 as a planned inspection, in Baltimore.

That inspection ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $1,749 and still stand at $1,749.

Fall protection systems comes up most often in these citations: 2 items under 1926.502.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Mission Drywall and Ceiling, LLC averages $1,749 (1 cited inspection).

Mission Drywall and Ceiling, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

185employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Mission Drywall and Ceiling, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342128063 OPENED FEB 24, 2017Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 8, 2017

20 E Franklin St, Baltimore, MD 21201 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$875$875Apr 25, 2017Final
Citation 1, item 2
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$437$437Apr 25, 2017Final
Citation 1, item 3
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$437$437Apr 25, 2017Final
Citation 2, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Apr 25, 2017Final
Citation 2, item 2
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Apr 25, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.501(b)(4)(ii)

(ii) Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(1)

(1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph.

29 CFR 1926.503 · Fall protection training in construction

Other structural steel and precast concrete contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.