OSHA SearchOSHA records by employer

Miter Masonry Contractors Inc: OSHA inspections and violations

Florence, Kentucky · Masonry Contractors · NAICS 238140

4inspections
2citation items
$3,500current penalties
Mar 9, 2017last inspection

Miter Masonry Contractors Inc has 4 OSHA inspections on record in Kentucky, the first in 1989.

OSHA's last visit started on Mar 9, 2017, in Newport.

Across those inspections OSHA issued 2 citation items: 2 other-than-serious.

OSHA proposed $3,500 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Miter Masonry Contractors Inc averages $3,500 over 1 cited inspection in that time.

Miter Masonry Contractors Inc: OSHA citation items per year, 1989 to 2017
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

189employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Miter Masonry Contractors Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342164480 OPENED MAR 9, 2017Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Feb 2, 2018

219 Highland Ave, Newport, KY 41075 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Other-than-serious$3,500$3,500Jun 14, 2017Final

Inspection 308731462 OPENED APR 23, 2005Closed

Unprogrammed other · Complete · Safety · 15 employees at the site · Closed Apr 23, 2005

11132 Madison Pike, Independence, KY 41051 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308398486 OPENED MAR 9, 2005Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Mar 14, 2005

8300 Us 42, Florence, KY 41042 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 2784296 OPENED MAR 14, 1989Closed

Planned · Complete · Safety · 14 employees at the site · Closed Apr 20, 1989

9000 Spruce Dr., Florence, KY 41042 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(2) · Scaffolds, general requirements
Other-than-serious$0$0Apr 19, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(2)

(2) Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds, shall be capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist, or 1.5 (minimum) times the tipping moment imposed by the scaffold operating at the stall load of the hoist, whichever is greater.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

Other masonry contractors employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.