OSHA SearchOSHA records by employer

MJ Stucco, Inc.: OSHA inspections and violations

Skokie, Illinois · Masonry Contractors · NAICS 238140

2inspections
7citation items
$14,778current penalties
May 22, 2019last inspection

OSHA has inspected MJ Stucco, Inc. 2 times in Illinois since 2019.

The latest one began on May 22, 2019 as a planned inspection, in La Grange.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $25,573 and now stand at $14,778, 42% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and MJ Stucco, Inc. averages $7,389 (2 cited inspections).

MJ Stucco, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

426employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch MJ Stucco, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344028659 OPENED MAY 22, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 25, 2021

741 S. Stone Ave, La Grange, IL 60525 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,705$855Jul 10, 2019Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,978$1,989Jul 10, 2019Final
Citation 1, item 3
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,978$1,989Jul 10, 2019Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,978$1,989Jul 10, 2019Final
Citation 1, item 5
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$3,978$1,989Jul 10, 2019Final
Citation 1, item 6
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,978$1,989Jul 10, 2019Final

Inspection 343989778 OPENED MAY 7, 2019Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 14, 2024

5149 Farwell Ave., Skokie, IL 60076 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$3,978$3,978May 9, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

Other masonry contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.